سعر جيد  عبر الإنترنت

تفاصيل المنتجات

المنزل > المنتجات >
اختبار الاختراق
>
Twin NiCr Sensitivity Panels NiCr Twin Cracked TypeⅠASTM E1417 AMS 2647D ISO 3452 JIS Z 2343-3

Twin NiCr Sensitivity Panels NiCr Twin Cracked TypeⅠASTM E1417 AMS 2647D ISO 3452 JIS Z 2343-3

الاسم التجاري: HUATEC
رقم الموديل: اكتبⅠ
موك: 1 قطعة
تفاصيل التغليف: حزمة التصدير القياسية
شروط الدفع: T/T ، Paypal ، Western Union
معلومات تفصيلية
مكان المنشأ:
بكين
إصدار الشهادات:
ISO, CE, GOST
مادة:
NiCr
لون:
فضي
الاسم:
اكتب عينة الاختبار
المعايير:
ISO 3452-3: 1998 (E) ، JIS Z 2343-3: 2001
اسم المنتج:
التفتيش المخترق الصبغ
معيار:
JIS Z 2343-3: 2001
القدرة على العرض:
500pcs في الشهر
إبراز:

nicr penetrant testing,penetrant testing panels

,

penetrant testing panels

وصف المنتج

TypeⅠASTM E1417, AMS 2647D, ISO 3452-3, JIS Z 2343-3 Twin NiCr Sensitivity Panels NiCr Twin Cracked Penetrant Test Panels

 

TypeⅠPenetrate block :ISO 3452-3:1998(E),JIS Z 2343-3:2001

Twin NiCr Sensitivity Panels,NiCr Twin Cracked Penetrant Test Panels

ISO 3452-3 Type 1 Test Panel

 

The NiCr Twin Cracked Penetrant Test Panels are used for comparing and evaluating sensitivity and performance of Dye Penetrants.

They are available in 10, 20, 30 and 50 microns (0.0004, 0.0008, 0.0012, 0.002 inch) flaw depth.

Each set consists of a pair of identical panels marked A and B with manufacturer`s certification and crack photograph.

These panels are made by plating hard Nickel Chromium alloy on a 2mm thick brass substrate and stressing the panel in tension. The hard NiCr is brittle in comparison to the brass substrate so that the cracks created in the plated layer are limited to the thickness of the layer. The panel is then cut in half perpendicular to the direction of the cracks thus creating a matching pair of virtually identical cracks of controlled depth.

NiCr Panels are used to compare new and used penetrants and can also be used for comparing performance of different penetrant materials or different processing techniques.

Sensitivity* (unofficial) Fluorescent Penetrant Sensitivity Levels are established by the USAF Laboratory under highly controlled conditions. Sensitivity testing is not something the penetrant manufacturer or user can do. What you can do is compare samples using appropriate NiCr Cracked Panels.

 

 

Crack Depth

 

Level

50 μm 1, 2, 3, 4
30 μm 2, 3, 4
20 μm 3, 4
10 μm 4


Guaranteed to be equivalent to both Sherwin and Magnaflux supplied panels.

Specifications Compliance: ASTM E1417, AMS 2647D, ISO 3452-3, JIS Z 2343-3

 

 

Standard delivery:

YM-B block 1 set

Calibration certificate 1 pc

Case 1 pc 

التقييمات والمراجعات

التصنيف العام

5.0
بناءً على 50 مراجعة لهذا المورد

لقطة التصنيف

التالي هو توزيع جميع التقييمات
5 النجوم
100%
4 النجوم
0%
3 النجوم
0%
2 النجوم
0%
1 النجوم
0%

جميع المراجعات

1
12
Brazil Oct 29.2025
123